Subassemblies for Flexible Endoscope Repair
Insertion Tube Assemblies
for Flexible Endoscope Repair
OPTIM Incorporated manufactures a line of nine insertion
tube subassemblies, as well as endfitting and coil pipe components, for
use in repairs of the most popular colonoscopes, gastroscopes and bronchoscopes.
As an ISO 9001 certified, FDA registered, GMP compliant manufacturer of
flexible fiberoptic endoscopes and scope assemblies for our private label
customers, OPTIM Incorporated is now offering these insertion tubes to
endoscope repair facilites.
OPTIM Incorporated insertion tubes are manufactured with USP Class VI
materials and are compliant with the ISO 10993 Specification for Biological
Evaluation of Medical Devices. The tube assemblies are compatible with
STERIS , STERRAD , Glutaraldehyde, and EtO sterilization methods.
Tube with proximal fitting attached and distal fitting unattached. No coil pipes. May be used to repair models listed |
Tube Dimensions |
004700 / Colonoscope (CF 100L) | 13.1mm x 1630mm |
004703 / Colonoscope (CF100TL) | 13.1mm x 1613mm |
004715 / Colonoscope (CF1T100L) | 13.84mm x 1629mm |
004945 / Colonoscope (CFQ140L) | 13.1mm x 1625mm |
004861 / Colonoscope (EC3801L) | 12.9mm x 1676mm |
004706 / Gastroscope (GIF 100) | 9.55mm x 1016mm |
004709 / Gastroscope (GIF 130) | 9.8mm x 1016mm |
004718 / Gastroscope (GIFXQ140) | 9.55mm x 1027mm |
004712 / Bronchoscope (BFP20D/30) | 5.26mm x 542mm |
Coil pipes silver-soldered to distal fitting | Compatability |
004908 / Colonoscope (CF100L) | For 004700 Colonoscope |
004704 / Colonoscope (CF100TL) | For 004702 Colonoscope |
004909 / Colonoscope (CF1T100L) | For 004715 Colonoscope |
004943 / Colonoscope (CFQ140L) | For 004946 Colonoscope |
004707 Gastroscope (GIF 100) | For 004706 Gastroscope |
004710 / Gastroscope (GIF130) | For 004709 / Gastroscope |
004719 / Gastroscope (GIFXQ140) | For 004718 Gastroscope |
004713 / Bronchoscope (BFP20D/30) | For 004712 Bronchoscope |
004935 / Video Bronchoscope | For 5.26mm video bronchs |
Distal and Proximal Endfittings
May be used to repair: | Distal Endfitting | Proximal Endfitting |
CF100L | 004691 | 004697 |
CF100TL | 004699 | 004721 |
CF1T100L | 004730 | 004727 |
CFQ140L | 004942 | 004941 |
GIF100 | 004722 | 004723 |
GIF130 | 004724 | 004725 |
GIFXQ140 | 004728 | 004729 |
BFP20D/BFP30 (fiberscope) |
004731 | 004726 |
Coil Pipes (Spring Guides)
May be used to repair: | Part Number | Unit Length |
Colonoscopes - all models | 004161S | 12 feet |
Gastroscopes -all models | 004127S | 4 feet |
Bronchoscopes -all models | 408288 | 4 feet |
OPTIM Incorporated, 64 Technology Park Road, Sturbridge, MA 01566-1262. Tel: 508-347-5100; Fax: 508-347-2380.