Subassemblies for Flexible Endoscope Repair

Source: OPTIM Incorporated
Insertion Tube Assemblies for Flexible Endoscope Repair

Insertion Tube Assemblies for Flexible Endoscope Repair

OPTIM Incorporated manufactures a line of nine insertion tube subassemblies, as well as endfitting and coil pipe components, for use in repairs of the most popular colonoscopes, gastroscopes and bronchoscopes.

As an ISO 9001 certified, FDA registered, GMP compliant manufacturer of flexible fiberoptic endoscopes and scope assemblies for our private label customers, OPTIM Incorporated is now offering these insertion tubes to endoscope repair facilites.

OPTIM Incorporated insertion tubes are manufactured with USP Class VI materials and are compliant with the ISO 10993 Specification for Biological Evaluation of Medical Devices. The tube assemblies are compatible with STERIS , STERRAD , Glutaraldehyde, and EtO sterilization methods.



Tube with proximal fitting attached
and distal fitting unattached. No coil pipes.
May be used to repair models listed
Tube Dimensions
004700 / Colonoscope (CF 100L) 13.1mm x 1630mm
004703 / Colonoscope (CF100TL) 13.1mm x 1613mm
004715 / Colonoscope (CF1T100L) 13.84mm x 1629mm
004945 / Colonoscope (CFQ140L) 13.1mm x 1625mm
004861 / Colonoscope (EC3801L) 12.9mm x 1676mm
004706 / Gastroscope (GIF 100) 9.55mm x 1016mm
004709 / Gastroscope (GIF 130) 9.8mm x 1016mm
004718 / Gastroscope (GIFXQ140) 9.55mm x 1027mm
004712 / Bronchoscope (BFP20D/30) 5.26mm x 542mm
 
Coil pipes silver-soldered to distal fitting Compatability
004908 / Colonoscope (CF100L) For 004700 Colonoscope
004704 / Colonoscope (CF100TL) For 004702 Colonoscope
004909 / Colonoscope (CF1T100L) For 004715 Colonoscope
004943 / Colonoscope (CFQ140L) For 004946 Colonoscope
004707 Gastroscope (GIF 100) For 004706 Gastroscope
004710 / Gastroscope (GIF130) For 004709 / Gastroscope
004719 / Gastroscope (GIFXQ140) For 004718 Gastroscope
004713 / Bronchoscope (BFP20D/30) For 004712 Bronchoscope
004935 / Video Bronchoscope For 5.26mm video bronchs

Distal and Proximal Endfittings

May be used to repair: Distal Endfitting Proximal Endfitting
CF100L 004691 004697
CF100TL 004699 004721
CF1T100L 004730 004727
CFQ140L 004942 004941
GIF100 004722 004723
GIF130 004724 004725
GIFXQ140 004728 004729
BFP20D/BFP30
(fiberscope)
004731 004726

Coil Pipes (Spring Guides)

May be used to repair: Part Number Unit Length
Colonoscopes - all models 004161S 12 feet
Gastroscopes -all models 004127S 4 feet
Bronchoscopes -all models 408288 4 feet

OPTIM Incorporated, 64 Technology Park Road, Sturbridge, MA 01566-1262. Tel: 508-347-5100; Fax: 508-347-2380.